Doepfer A-154 Sequencer Controller Manual do Utilizador Página 1

Consulte online ou descarregue Manual do Utilizador para Áudio Doepfer A-154 Sequencer Controller. Doepfer A-154 Sequencer Controller User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 16
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
doepfer
System A - 100
Sequencer Controller
A-154
1
1. Introduction
Module A-154 is a supplement to the Analog/Trigger
Sequencer A-155. It offers a lot of new features that are
not available in the basic control unit of the A-155. The
A-154 is used to replace the control unit of one or two
A-155, i.e. the section marked "Control" with Start / Stop
/ Step / Reset buttons and inputs in the upper left corner
of the A-155 front panel. If the A-154 is used to control
the A-155 the control section of the A-155 is put out of
action.
These are the most important features of the A-154:
5 different running modes: forward, backward, pen-
dulum, random, CV controlled step adressing. All
modes are available as loop or one-shot
Manual and voltage controlled selection (with at-
tenuator) of the running mode
5+1 LED display for the 5 different current modes
and one LED for loop/one-shot display
Manual and voltage controlled selection (with at-
tenuator) of first and last step of the sequence
In the "CV Controlled Step Address" mode the First
Step section is used to determine the active sequen-
cer step (in this mode the first/last step feature is not
available). Consequently manual and voltage con-
trolled selection of the active step is possible
Internal voltage controlled clock generator with
manual and voltage controlled (with attenuator)
clock rate, enables variable time length for each
step, e.g. controlled by one of the analog rows of the
A-155
Skipping of steps, e.g. the gate row of the A-155 can
be used to control the skipping of steps
LED display of the clock signal
Manual and voltage controlled (with attenuator)
pulse length of the clock signal. This features enab-
les different gate length (at the same clock rate) for
each step, e.g. one of the CV outputs of the A-155
can be used to control the PW
One or two A-155 can be controlled from the A-154
8/16 step mode: In combination with two A-155 one
can select between parallel (8 steps) or serial ope-
ration (16 steps). The serial operation requires addi-
tional voltage controlled switches (e.g A-150)
Manual and voltage controlled selection between
"old" control unit of the A-155 and A-154 control
(A-154 Master on/off function)
With the One-Shot modes the A-155/A-154 combi-
nation can be used e.g. as a complex envelope
generator. One analog row determines the levels of
the envelope. The second analog row can be used to
adjust the time length for each step
The A-154 requires at least one A-155
Vista de página 0
1 2 3 4 5 6 ... 15 16

Resumo do Conteúdo

Página 1 - 1. Introduction

doepferSystem A - 100Sequencer Controller A-15411. IntroductionModule A-154 is a supplement to the Analog/TriggerSequencer A-155. It offers a lot o

Página 2

A-154 Sequencer Controller System A - 100doepfer10Fig. 2 shows how to patch the upper trigger rows and theupper CV rows of two A-155 with A-154 a

Página 3 - 2. Basic principles

doepferSystem A - 100Sequencer Controller A-15411The position of switch 7a determines if the A-154 mana-ges 8 or 16 steps. Only in position "16

Página 4 - 3. Overview

A-154 Sequencer Controller System A - 100doepfer125. User Examplesnot yet ready

Página 5

doepferSystem A - 100Sequencer Controller A-15413Appendix: Connection A-154 – A-155(1) Disconnect the 10 pin ribbon cable leading from the connector

Página 6 - 4. Controls

A-154 Sequencer Controller System A - 100doepfer14Two 10 pin ribbon cables come from the A-154. One (A) with a 10 pin female connector (A1) at it

Página 7

doepferSystem A - 100Sequencer Controller A-15415(4) Connect B1 with the female connector at the end of the ribbon cable that was removed from ST2 o

Página 8

A-154 Sequencer Controller System A - 100doepfer16In case that two A-155 have to be controlled by the A-154 the second A-155 ha

Página 9

A-154 Sequencer Controller System A - 100doepfer2Fig.1: Overall view

Página 10 - System A - 100

doepferSystem A - 100Sequencer Controller A-15432. Basic principlesThe current step position of the A-155 is determinedby the current address of th

Página 11

A-154 Sequencer Controller System A - 100doepfer43. Overview!1b1a"2b2a§3b3a$4b4a%5b5a&a6a7a&b6b/&c6c&d6d9(81c)7b

Página 12 - 5. User Examples

doepferSystem A - 100Sequencer Controller A-1545Controls:1a Manual Mode: Manual Mode control1b Mode CV: Attenuator for CV input !1c Mode display (6

Página 13

A-154 Sequencer Controller System A - 100doepfer64. Controls1a Manual Mode (knob)/ 1c Anzeige (LEDs)! Mode CV (socket) / 1b Mode CV (knob)Contro

Página 14

doepferSystem A - 100Sequencer Controller A-15472a Manual First (knob)2b First CV (knob) / " First CV (socket)3a Manual Last (Regler)3b Last CV

Página 15

A-154 Sequencer Controller System A - 100doepfer8Another example is to control the clock rate by one ofthe A-155 CV outputs. This leads to a diff

Página 16

doepferSystem A - 100Sequencer Controller A-1549Operating the reset button prepares the sequencer tojump to the first step as soon as the next clock

Comentários a estes Manuais

Sem comentários